Reliance 6-06: No Heat, Light, or a Leak

The Short Answer: A Reliance 6-06 is a 6-year AO Smith / State builder tank, gas or electric, not a mystery brand. Cold electric is breaker, ECO, or a 4500 W element. Cold gas is the status LED, FVIR, or a dead spark. Water on the floor is a drain, T&P, nipple, or a dead shell. Split fuel, then test that path. Ignition-only: won’t light. Wet pan: Reliance leaking.

Licensed local technicians

Reliance 6-06 cold, flashing, or wet?

Connect with a licensed 24/7 technician in your zip code right now.

No charge to connect. You only pay the plumber you hire.

Search Intent & The Real Problem

The rating plate says 6-40-6xxx or 6-50-6xxx — people search “606.” Home Depot and Lowe’s sold these for years. Same guts as State / American / Craftmaster: plastic drain, dual 4500 W elements or a millivolt/electronic gas valve, FVIR screen on gas. Forums will sell you a company history. You need a flash count, an ohm reading, or a dry part.

They treat “606” as a 6-gallon point-of-use cube. Most 6-06 searches are 40- and 50-gallon 6-year tanks. They paste a Rheem 5-flash chart onto a Reliance gas LED. They condemn the tank because the plastic drain weeps.

Step-by-Step Troubleshooting

Step 1: Read the plate — fuel, gallons, and the actual complaint

What you have Path
Electric, totally cold Breaker, ECO, upper element
Electric, short hot then cold Lower element / lower thermostat
Gas, will not light Cock, LED, spark, FVIR
Gas, lights then dies Thermopile / pilot / lockout
Pan wet, jacket dry Drain, T&P, nipple, element gasket
Jacket wet, rust at the seam Tank — replacement
  • What to look for: Rating plate (E electric, G or natural/LP gas). Photo of the gas-valve sticker or the thermostat door. That sticker wins.
  • Required tools: Flashlight, phone camera.

Step 2: Electric 6-06 — breaker, fill, ohms

  • What to look for: Double-pole 30 A off or half-tripped. Tank full before any reset — dry-fire after a drain is this failure. Upper ECO once after the tank is full and cool. Wires lifted, power verified dead: a healthy 4500 W / 240 V element reads ~12–13 Ω (~18.8 A). Infinite = open. Screw-to-tank continuity = grounded.
  • Required tools: Meter, breaker locked. No meter = hire it.

Brown thermostat plastic is burn-up. A breaker that will not reset is a short. Do not hold it on.

Step 3: Gas 6-06 — status light, not a match ritual

Typical Honeywell-family sticker (confirm yours):

LED Meaning
Short flash ~every 4 seconds Idle
Heartbeat Calling for heat — no fault
1 flash, pause Low flame — still trying
4 flashes ECO / high-limit lockout
6-1 flashes Failed trial for ignition
7+ flashes Flammable vapor / FVIR
  • What to look for: Appliance cock open, other gas loads lighting. One lighting cycle per the jacket. Lint in the FVIR arrestor. Do not jumper the vapor sensor — chamber sensor.
  • Required tools: Eyes. Manometer is licensed: NG ~3.5–7 in. w.c. / LP ~10–11 in. w.c. — confirm the rating plate.

No flame at all is won’t light. Do not purge fittings.

Step 4: Leak — paper-towel the source

  • What to look for: Bead on the plastic drain = valve, not tank. T&P pipe wet = pressure or temperature — gauge the house (static over 80 psi) and the expansion tank. Typical T&P 150 psi / 210°F. Element gasket wet, jacket dry = gasket. Foam wet with rust at the base = dead tank. Same map as bottom leak.
  • Required tools: Paper towel, flashlight. Hose-bib gauge if the T&P is the wet pipe.

Do not epoxy the shell.

Step 5: When the 6-year tank is actually done

  • What to look for: Six to twelve years in hard water, anode never changed, popping for years, rusty flush water, jacket weep, or water in the gas burner tray. A 6-06 was built to a 6-year warranty. Parts on a leaking shell are a delay.
  • Required tools: None. Replacement is licensed in many cities.

When DIY Ends: Calling a Licensed Pro

Stop if the jacket is wet, the bushing spins, you smell gas, the T&P is streaming, the thermostat is charcoal, or a dry-fire already happened. You may lock the breaker, count flashes, fill the tank, and ohm elements. You may not jumper an ECO, cap a T&P, or thread on a “universal” gas valve. A licensed plumber replaces a leaking 6-06 the same day — cheaper than a collapsed subfloor.

Frequently Asked Questions

Q: What is a Reliance 6-06 water heater? A: A 6-year AO Smith / State residential tank, usually 40 or 50 gallons, gas or electric. The plate looks like 6-40-6xxx or 6-50-6xxx. It is not a 6-gallon cube unless the plate says so.

Q: Why is my Reliance 6-06 not heating? A: Electric: breaker, ECO, or an open element (~12–13 Ω healthy at 4500 W / 240 V). Gas: closed cock, status-light lockout, or FVIR. A wet jacket is a new tank, not a new element.

Q: Can I still get parts for a Reliance 6-06? A: Elements, thermostats, drains, and many gas controls are family parts. A leaking shell is not a parts problem. Hire a licensed plumber if the jacket is wet or the gas valve is in lockout.