The Short Answer: A standing pilot that lights while you hold the knob and goes out when you let go usually means the flame sensor (a thermocouple or thermopile) is not proving the flame to the gas valve. A pilot that stays lit for a while and then dies points more to combustion air, a clogged flame arrestor, a tripped thermal switch, or venting. Relight once per the label; then call a technician.
First, confirm you have a standing pilot
This page covers tanks with a small pilot flame that burns all the time and a gas valve knob marked OFF, PILOT and ON. Many power-vent models with a blower and power cord have no pilot; a hot-surface or spark igniter lights the burner, and the label says not to light it by hand. On those, a flame that will not stay on is an ignition or lockout problem; see whether an electronic-ignition heater can be lit by hand and the pilot and ignition problems hub.
Two kinds of standing-pilot controls
The likely cause depends on which gas valve the tank has.
| What you see on the gas valve | What proves the flame | What “won’t stay lit” usually points to |
|---|---|---|
| Knob only, no status light (mechanical valve) | A thermocouple, a thin copper lead from the pilot to the valve | Thermocouple not hot enough or failed, weak pilot flame, tripped thermal switch, or the valve itself |
| Knob plus a small status light (electronic valve, often Honeywell/Resideo on A. O. Smith family tanks) | A thermopile, a heavier two-wire sensor that powers the control | Low thermopile output, a tripped thermal switch, or the control; the status light pattern on the label helps narrow it |
A. O. Smith’s own service charts describe both types on its residential atmospheric tanks: the mechanical valve uses a thermocouple, and the electronic valve uses a thermopile and a status light that flashes steadily once the pilot is proven (mechanical valve chart (opens in a new tab), electronic valve chart (opens in a new tab)). State’s Select direct-vent sheet likewise lists a thermopile-powered electronic gas valve with an LED status indicator and a push-button piezo ignitor (State SRGSS04812 (opens in a new tab)). Flash meanings differ between controls, so read the chart printed on your valve rather than a chart from another brand.
Which brand family is your heater?
Store and private-label names come from a few manufacturers, which matters when looking up the right manual and parts.
- State, State Select, American, and Whirlpool tanks: A. O. Smith bought State Industries in 2001 and GSW, the parent of American Water Heater, in 2006 (A. O. Smith history (opens in a new tab); Contractor, 2006 (opens in a new tab)). Whirlpool-brand water heaters sold at Lowe’s were supplied by American Water Heater under a license announced in 2000 (Plumbing & Mechanical (opens in a new tab)). Confirm with the rating plate.
- GE tanks: In 1999 Rheem agreed to build GE-brand water heaters for The Home Depot (Supply House Times (opens in a new tab)). GE-branded heaters from other years may have a different maker; the rating plate names it. For Rheem-built tanks, see Rheem pilot light will not stay lit.
Common causes, by when the pilot goes out
| When it goes out | Likely causes |
|---|---|
| Lights, then goes out as soon as you release the knob | Thermocouple or thermopile not heated enough or failed; a loose sensor connection at the valve; a tripped thermal switch; a failed gas valve |
| Lights with a small, yellow or lazy flame that does not wrap the sensor | Partially blocked pilot orifice, low gas supply, or poor combustion air |
| Stays lit for minutes or hours, then goes out | Starved combustion air, a lint- or dust-clogged flame arrestor, a downdraft or blocked vent, or exhaust fans pulling air from the space |
| Goes out in windy or very cold weather | Downdraft in the vent; see pilot goes out in cold weather |
| Will not light at all | Gas supply off, no spark from the igniter, or a blocked pilot orifice |
Residential atmospheric gas tanks built to the flammable vapor ignition resistant (FVIR) requirements of ANSI Z21.10.1 have a sealed combustion chamber with a flame arrestor at the base, and A. O. Smith family tanks add a thermal switch near the combustion chamber. A. O. Smith’s charts treat a tripped thermal switch as a sign of an air-supply problem: the room must supply enough combustion air, and the flame arrestor and air filter may need cleaning.
What you can check safely
- No gas smell first. If you smell gas at any point, stop and leave.
- The gas supply. The handle on the shutoff valve in the gas line to the heater is open when it is parallel to the pipe. Check that other gas appliances work. On propane, check that the tank is not empty.
- The lighting label. Follow the lighting instructions printed on the heater exactly, once. They tell you how long to wait after turning the knob off, how to use the igniter button, and how long to hold the knob. The pilot can be hard to see in daylight; A. O. Smith suggests dimming the room lights to look through the viewport.
- The status light, if the valve has one. Count the flashes and compare them with the chart on the valve or in the manual.
- The space around the heater. Note lint, dust, sawdust, or stored chemicals near the base, a closet door that has been replaced with a solid one, and whether the pilot dies when a dryer, bath fan, or range hood runs. Keep gasoline, paint, and solvents out of the room.
- Write down the pattern. When it went out, how long it stayed lit, and the model and serial number from the rating plate.
If the pilot will not stay lit after one careful attempt, set the knob to OFF as the label directs and stop. Repeated relighting does not fix a failed sensor and can leave unburned gas in the combustion chamber.
What the technician will check
A technician confirms the gas supply and checks that the pilot flame is the right size and fully surrounds the sensor tip. They measure the thermocouple or thermopile output against the control maker’s specification to separate a weak sensor from a failed valve. If the thermal switch tripped, they find out why before resetting it, since it responds to poor combustion air or flame rollout. They inspect the flame arrestor and burner, run a draft test at the draft hood, and check the vent. Opening the sealed burner door and replacing a sensor, pilot assembly, or gas valve are gas and combustion work, and the door gasket must be resealed afterward. For more on the sensor itself, see thermocouple problems.
Repair or replace
A sensor, pilot assembly, thermal switch, or gas valve is a part replacement. Cleaning a flame arrestor or fixing combustion air is often the whole fix. A leaking tank means replacement, and A. O. Smith’s labels say a gas heater that has been under water must be replaced, not repaired.
Frequently Asked Questions
Q: Why does the pilot go out the moment I let go of the knob? A: While you hold the knob, you are holding the gas valve open by hand. When you release it, the valve stays open only if the thermocouple or thermopile is producing enough power from the pilot flame. If it goes out right away, the sensor, its connection, the thermal switch, or the valve is the likely cause. Holding the knob longer than the label says will not fix it.
Q: My pilot stays lit for a few hours, then goes out. Is that the thermocouple? A: Sometimes, but a delayed outage often points to combustion air or a clogged flame arrestor, which can trip the thermal switch on FVIR tanks that have one. A technician should find the cause before parts are replaced.
Q: Can I replace the thermocouple myself? A: On a sealed FVIR burner it means opening the combustion chamber and disconnecting a fitting at the gas valve, so it is technician work. Your part is the lighting label, the gas shutoff position, and observations.
Manuals and supporting references
These links distinguish general safety information from model-specific documentation. A manual directory helps you locate your unit’s instructions; it does not establish that every model uses the same parts, codes, or test values.
- A. O. Smith University: mechanical residential gas valve troubleshooting (opens in a new tab)A. O. Smith family atmospheric gas tanks with a mechanical (thermocouple) gas valve. Professional diagnostic chart.
- A. O. Smith University: electronic residential gas valve troubleshooting (opens in a new tab)A. O. Smith family atmospheric gas tanks with a thermopile-powered electronic gas valve and status light. Professional diagnostic chart.
- State Water Heaters: Select direct vent residential gas specification (SRGSS04812) (opens in a new tab)State Select direct-vent gas models listed in the 2014 sheet: thermopile-powered electronic gas valve, LED status indicator, piezo ignitor.
- A. O. Smith company history (opens in a new tab)A. O. Smith acquisition of State Industries (2001) and GSW (2006).
- Contractor: A.O. Smith buys American Water Heater parent (2006) (opens in a new tab)GSW, parent of American Water Heater, acquired by A. O. Smith in April 2006.
- Plumbing & Mechanical: American Water Heater to supply Lowe's (2000) (opens in a new tab)2000 license under which American Water Heater supplied Whirlpool-brand water heaters to Lowe's.
- Supply House Times: Rheem to make G.E. water heaters (1999) (opens in a new tab)1999 agreement for Rheem to build GE-brand water heaters sold through The Home Depot. Does not cover every later GE-branded model.
- PG&E: recognizing and responding to a gas leak (opens in a new tab)Emergency actions for suspected fuel-gas leaks.
- CPSC: carbon monoxide fact sheet (opens in a new tab)Carbon monoxide hazards and emergency response.
- A. O. Smith: model and manual lookup (opens in a new tab)Find the instructions for the model on your rating plate; this directory does not verify a particular error-code meaning.
Editorial standards and corrections · Prepare a useful service request