Honeywell Water Heater Control: Thermocouple or Not?
On this page (6 sections)
The Short Answer: Honeywell (now Resideo) makes the gas control, not the water heater, and its water heater controls use different flame sensors. Older standing-pilot controls with an OFF/PILOT/ON knob use a thermocouple. Electronic controls with a status light are powered by a thermopile and won’t work with a thermocouple. Identify the control, rule out a draft or lint problem, then have a technician replace the right part.
Which Honeywell control do you have?
The word “Honeywell” or “Resideo” on the gas control tells you who made the valve. The water heater could be an A. O. Smith, State, Reliance, American, Rheem, or another brand. Look at the control and the lighting label on the heater:
| What you see on the control | Flame sensor it uses | Does a standard thermocouple fit? |
|---|---|---|
| Knob marked OFF / PILOT / ON, red reset or pilot button, no status light | Thermocouple: a thin copper tube with a nut at the valve | Yes, if it is the correct length and type for that control |
| Status light (LED) on the control and a lighting label that describes a pilot and igniter | Thermopile: produces more voltage and powers the control’s electronics | No |
| No pilot; electronic ignition with a blower on top of the heater | Neither; power vent with electronic ignition | No |
If your control has a status light, a pilot that won’t stay lit is usually a thermopile, pilot, or air-supply issue. The light pattern on the label can help narrow it down. See water heater thermocouple problems for how the two sensors differ.
Why the pilot may not be staying lit
A new thermocouple is a common first guess, but other causes look the same:
- Pilot flame too small or yellow. A dirty pilot orifice or a starved air supply produces a weak flame that doesn’t heat the sensor enough.
- Sensor tip out of the flame. If the bracket is bent or the tip has moved, even a good thermocouple will not hold.
- Lint or dust on the air intake. Flammable-vapor-resistant (FVIR) heaters draw air through a screen or arrestor near the base. When it clogs, the pilot may light and then go out.
- Drafts. Pilots that go out when a nearby fan or furnace starts point to a draft or venting problem.
- The gas control. If a correct sensor in a good flame still doesn’t hold the pilot, the safety magnet inside the valve, or its built-in overheat cutoff, may be at fault. That means a new control, not another sensor.
What you can check safely
- Follow the lighting instructions on the label on your heater. Do not improvise steps.
- Watch the pilot through the sight window if you can. A healthy pilot is steady, mostly blue, and wraps the tip of the sensor.
- Vacuum dust and lint from the floor around the base of the heater and from the outside of the air-intake screen, if your owner’s manual describes doing so.
- Move gasoline, paint, and solvents away from the heater.
- Note whether the pilot goes out right away when you release the knob, or after the burner has run for a while. Tell the technician which.
What the technician will check
A technician will identify the control model, measure the output of the thermocouple or thermopile while the pilot is burning, and check the pilot flame, orifice, and sensor position. On FVIR heaters they open the sealed combustion door and refit it with a new gasket where required. If the sensor output is in range and the pilot still won’t hold, they will look at the gas control itself and its overheat cutoff. They also leak-test any gas connection they disturbed.
Repair or replace
A thermocouple or thermopile is an inexpensive part. A gas control costs more but is still a repair on a sound tank. If the tank is leaking or rusted near the base, or the heater is near the end of its service life, replacing the heater may make more sense. Related: pilot won’t stay lit after replacing the thermocouple and why won’t my gas water heater stay lit.
Frequently Asked Questions
Q: Can I put a universal thermocouple on any Honeywell water heater valve? A: Only on standing-pilot controls designed for a thermocouple. Controls with a status light use a thermopile and need the manufacturer’s matched part.
Q: Why did the pilot still go out after a new thermocouple? A: The pilot flame, sensor position, air supply, a draft, or the gas control itself may be the real cause. A technician can measure the sensor output to tell these apart.
Q: Is replacing a thermocouple a homeowner job? A: On most modern heaters the thermocouple passes through a sealed combustion door, and the door gasket and seal matter for safety. Have a qualified technician do it so the chamber is resealed and the connections are checked.