Thor Water Heater Dead? Read the Door Badge

The Short Answer: Thor Motor Coach does not build a “Thor” water heater. Four Winds, Chateau, ACE, Quantum, Hurricane, and cousins ship Suburban, Atwood/Dometic, Truma, or another tankless behind a Thor wall. Open the exterior door, read the badge, then follow that product. Smell propane, shut the bottles. Do not invent an OEM tank.

Licensed local technicians

Thor coach, no hot water?

Connect with a licensed 24/7 technician in your zip code right now.

No charge to connect. You only pay the plumber you hire.

Search Intent & The Real Problem

The sticker inside the coach says Thor. The shower is cold. Search results keep inventing a Thor-branded 6-gallon. I have never installed one. I have replaced Suburban SW6DE / SW10DE / SW16DE Phase 3 units, Atwood GC-series DSI tanks, and the occasional Truma AquaGo or Girard/Furrion tankless in the same bays. Wrong board, wrong electrode, melted harness. Start at the door badge, not the coach brand.

They write a “Thor water heater troubleshooting” ritual as if Thor stamped a unique tank. They mix Suburban Phase 3 boards with Atwood/Dometic boards. They send you after a standing-pilot thermocouple on a DSI heater that has none. They skip bypass valves, so a winterized tank gets a new board.

Step-by-Step Troubleshooting

Step 1: Open the door. Read the badge. There is no Thor OEM.

Door badge / what you see What it actually is Go here
Suburban, Phase 3, SW6DE / SW10DE / SW16DE DSI tank, dual-fuel common Suburban gas, Phase 3, SW10DE, igniter
Atwood or Dometic DSI tank Atwood clicking, Atwood electric
Truma AquaGo RV tankless Truma AquaGo
Girard, Furrion, other on-demand RV tankless, not a 6-gallon Tankless tech — not a Suburban board
Standing pilot, push-button piezo Older tank Piezo won’t spark
No heater in the bay, wall unit only Tankless or off-board Follow that jacket, not this table
  • What to look for: Model sticker on the interior of the access door or the tank jacket. Photograph it. Four Winds / Chateau / ACE on the coach skin does not pick the part.
  • Required tools: Flashlight, phone camera.

Step 2: Water in the tank, bypass in normal, which fuel is dead

  • What to look for: Three-valve bypass in the heat path, not winterize. Steady stream at a hot faucet, no sputter. A winterized tank is empty even if the lines are wet. Dual-fuel tanks: electric switch off while you diagnose gas so you do not dry-fire a ~1400 W / ~12 A element on a 10-gallon.
What works Look at first
Electric OK, gas dead LP, DSI/pilot, igniter, solenoid, ECO
Gas OK, electric dead 120 V, ECO, element
Both dead Empty tank, bypass, winterized, or no 12 V and no LP
Tankless: no tank 12 V, LP, water filter, freeze lock
  • Required tools: Cabinet diagram, a hot faucet.

Do not spark a DSI on a tank you have not filled. ECO after a dry fire will kill gas, electric, or both.

Step 3: 12-volt, LP, and the click — still not a DIY purge

  • What to look for: Coach battery / converter. DSI boards get stupid under ~10.5 V; rest voltage ~12.6 V is the baseline. Bottles open, pigtail not stripped, regulator not icing, stove or furnace lights. Stove works and the water heater does not = problem at the heater. Nothing LP lights = supply. Auto-stop regulators after a bottle swap mimic a dead heater.
  • Required tools: None on the flares. A DC meter if you are qualified.

Air after a bottle change can delay ignition. Loosening flares is how bays fill with gas.

Step 4: Decode ignition on that product

Sound / sight Meaning Next
No click at all (DSI) Switch, 12 V, fuse, ECO, board Power and ECO — Suburban reset
Click, no spark at the tip Cracked ceramic, burned lead, board Spark test, bottles closed
Spark, no flame Bottles, regulator, solenoid, spider nest Fuel path; electrode is fine
Lights, then drops Dirty rod, gap, flame sense, ECO Clean/regap or stop cycling
Tankless fan, then lockout That brand’s code Truma / Girard path, not a thermocouple
  • What to look for: Spark gap about 1/8” (3 mm). Do not short the electrode “to test the board.” Do not mix a Suburban 232307-class electrode with an Atwood rod.
  • Required tools: Ears at the exterior door. Bottles closed for a spark-only look.

Step 5: Electric half, ECO, and when the tank is actually dead

  • What to look for: Shore power or generator actually on the coach. ECO on the tank jacket after a dry fire or overheat — fill, one reset, stop if it will not latch. A wet bay or rusty tank skin is a vessel, not a board. Tankless units do not have a “Thor anode.”
  • Required tools: 120 V confirmed dead before you open a box. Licensed RV tech for element, solenoid, and board swaps you cannot match.

When DIY Ends: Calling a Licensed Pro

Stop at a propane smell, a heat-damaged harness, gas-solenoid replacement, a board you cannot match to the door badge, an ECO that will not latch, and any delayed-ignition bang. You may fill the tank, set bypass, confirm bottles and 12 V, and spark-test with fuel off. You may not loosen LP fittings or keep clicking a flooded burner. A mobile RV tech who stocks Suburban and Dometic is cheaper than a coach fire from a fifth trial — and cheaper than a “Thor” part that does not exist.

Frequently Asked Questions

Q: Why is my Thor water heater not working? A: Thor did not make the heater. Read the exterior-door badge. Suburban, Atwood/Dometic, Truma, or another tankless fail on LP, DSI/igniter, ECO, bypass, or 12 V — not on a Thor-branded tank.

Q: Is there a Thor OEM water heater I should order? A: No. Order Suburban, Dometic/Atwood, Truma, or the tankless on the rating plate. A “Thor water heater” listing is a listing.

Q: Gas is dead but electric still works in my Thor. Is the tank bad? A: No. On dual-fuel Suburban and Atwood tanks those are separate circuits. Electric working means the tank can hold water. Stay on the LP/ignition path.