Rinnai Code 25: Condensate Drain or Pump Fault

On this page (4 sections)

The Short Answer: Rinnai code 25 appears when condensate cannot drain. According to Rinnai, it is triggered by a float (safety) switch that trips when condensate backs up, and it can also occur when an external condensate pump stops working. Check that the pump has power and is pumping, that the drain line is not clogged or frozen, and that the line ends with an air gap. Then restart once.

Why condensing heaters need a clear drain

High-efficiency condensing Rinnai models pull so much heat from the exhaust that water vapor condenses inside the heater. That slightly acidic water has to leave through a trap and drain line, flowing downhill on its own or through a small pump. When it cannot, the water rises, the float switch closes, and the heater stops with code 25. Rinnai’s guide explains this on its code 25 page (opens in a new tab).

A full trap can also cause code 10 on SENSEI models, so you may see either number from the same blocked drain.

Rinnai’s checklist, and who does each step

Rinnai’s check Who What it looks like
Confirm power to the condensate pump Owner Pump plugged in, outlet working, GFCI not tripped
Check pump operation Owner can observe Reservoir empties when it fills; if the reservoir is full and the motor is silent, the pump has failed
Drain line not clogged or frozen Owner No kinks, sags holding water, or ice where the line exits the house
Drain line has an air gap Owner can observe; installer corrects The line should end above the drain opening, not pushed down into it
Wiring to the float switch and pump Technician Loose, damaged, or broken connections inside the cabinet

Thaw a frozen outdoor drain line with warm air or warm water on the outside of the tube, never an open flame. After the drain flows, turn the heater off and on once.

Signs it needs a technician

Book a technician if code 25 returns after the drain and pump are working, if you see water inside the cabinet or on the control board, or if the condensate pump fills quickly when no hot water has been used. A pump that fills with no burner operation may be collecting water from a different leak.

A replacement condensate pump or a rerouted drain line is a minor repair. Condensate-related codes do not, on their own, indicate a failed heat exchanger.

Related: water at a Rinnai exhaust after shutdown and a tankless leaking from the bottom.

Frequently Asked Questions

Q: Is water dripping from the condensate line a leak? A: No. On a condensing heater, water from the condensate drain while the burner runs is normal. Water from the cabinet, fittings, or relief valve is not condensate.

Q: Can a non-condensing Rinnai show code 25? A: Code 25 relates to the condensate system of condensing models. If your heater is a non-condensing model with a metal vent and you see 25, confirm the reading and look it up in your model’s manual.

Before you call a technician

Write down

  • The heater. Photograph the rating plate: brand, full model number, serial number, and fuel. The serial number usually encodes the manufacture date.
  • The exact code. Photograph the display, or count the flashes and the pause between groups. Note whether the code returns after one reset.

Stop and get help if

  • Gas or rotten-egg smell, or a CO alarm: leave now and call the gas utility or 911 from outside. Do not use switches or try to find the source.
  • A burner bang, flames outside the burner area, soot, or a smell of exhaust: turn the heater off at its control and do not relight it.
  • Never cap the relief valve, bypass a safety switch, or open gas, electrical, or sealed combustion parts.