Rinnai Code 11: No Ignition on a Rinnai Tankless
On this page (6 sections)
The Short Answer: On a Rinnai tankless, code 11 means “No Ignition”: the heater tried to light and never detected a flame. The owner checks Rinnai lists are simple: make sure the gas is on at the heater, the meter or the cylinder, and that a propane tank isn’t empty. Everything else on Rinnai’s list, from air in the gas line to the igniter, is work for a licensed professional.
What Rinnai’s manuals say
Every current Rinnai owner manual we checked, including the Sensei manual (opens in a new tab), lists code 11 as No Ignition (Heater Not Turning On). The remedy list is the same in substance across Sensei, RE/VE and Value Series models. Rinnai’s Value Series manual (opens in a new tab) shades most of the list as “licensed professional only”, which is a clear way to split it:
| Check | Who does it |
|---|---|
| Gas turned on at the water heater, gas meter or cylinder | Owner |
| Propane systems: there is gas in the tank | Owner |
| Heater properly grounded (plugged into a grounded outlet) | Owner can check the plug; wiring is professional work |
| Gas type and inlet gas pressure correct | Licensed professional |
| Air bled from gas lines | Licensed professional |
| Gas line, meter and regulator sized for the heater | Licensed professional |
| Flame rod connected and free of carbon | Licensed professional |
| Igniter and gas solenoid valves working | Licensed professional |
| Correct gas orifice; burner seated and clean | Licensed professional |
| Condensing (Sensei) models: condensate line not blocked | Licensed professional |
Rinnai’s service manual (opens in a new tab) applies code 11 to Sensei, Sensei RX/CX and non-Sensei models. For Sensei models its first steps match the owner list (verify all gas valves are open and check the propane tank), and next it has the technician verify that air was purged from the gas lines after installation.
When code 11 usually appears
- Right after installation. New gas piping often still holds air, which is why “bleed all air from gas lines” is on Rinnai’s list. That’s installer work, so call the installer back.
- After the gas was shut off. A meter swap, a gas leak repair or an unpaid bill can leave the gas off or partly closed at the meter or a branch valve.
- On propane. An empty or nearly empty tank, or a closed tank valve. Rinnai’s service manual also has the technician check that the propane tank is sized for the heater and that inlet pressure holds with the heater on high fire.
- After working fine for years. Gas supply is still the first thing to rule out. If the gas is fine, the cause is usually inside the heater: the igniter, flame rod, gas valve or a loose connection. The service manual notes that a loose (“floating”) flame rod can cause code 11 or 12.
What you can check safely
- Make sure the gas valve on the pipe to the heater is fully open, with the handle in line with the pipe.
- Check that other gas appliances (stove, furnace, dryer) work. If none do, call the gas utility.
- On propane, check the tank gauge and that the tank valve is open.
- Check that the heater’s power cord is plugged into its outlet and the outlet has power.
- Restart once: close all hot taps, turn the heater off with the On/Off button on the controller, turn it back on, and open a hot tap. Rinnai doesn’t publish a separate reset for code 11; this is the controller’s normal off-and-on.
If 11 returns, stop there. Each ignition attempt sends some gas through the burner, and repeated restarts won’t fix a supply or ignition fault. Write down the code, the model number from the rating label, and what changed recently, then call your installer or Rinnai.
Code 11, 12 or 10?
- 11: the burner never lit.
- 12: it lit, then lost its flame. See Rinnai code 12.
- 10: air supply or exhaust blockage (on condensing models, also a full condensate trap). See Rinnai code 10.
Other brands use 11 differently. On a Rheem or Richmond tankless, code 11 means the gas shut-off valve isn’t fully open; see Rheem code 11. Noritz uses 11 for ignition failure; see Noritz code 11.
What the technician will check
The technician measures inlet gas pressure with the heater firing, confirms the gas type matches the heater, and checks whether the gas line and meter are large enough for the heater’s input. Inside the heater they check the igniter, the flame rod and its wiring, the gas valves, and the burner surface for moisture or debris. On condensing models they also check the condensate drain. If air in a new gas line is the cause, purging it is part of correcting the installation.
Frequently Asked Questions
Q: Does code 11 mean gas is leaking? A: No. It means the heater didn’t detect a flame when it tried to light. A gas smell is a separate emergency: if you notice one, don’t restart the heater; leave and call the gas utility from outside.
Q: Can I bleed the air out of the gas line myself? A: No. Rinnai lists it as licensed-professional work, and opening gas fittings is unsafe. If the heater is newly installed, the installer should come back to do it.
Q: Is code 11 covered by warranty? A: That depends on the cause. A gas supply or installation problem isn’t a defect in the heater; a failed igniter or gas valve may be a covered part. Rinnai’s FAQ (opens in a new tab) suggests contacting Rinnai or your installer with the code; Rinnai’s support line is 1-800-621-9419.
Manuals and supporting references
These links distinguish general safety information from model-specific documentation. A manual directory helps you locate your unit’s instructions; it does not establish that every model uses the same parts, codes, or test values.
- Rinnai: Sensei condensing installation and operation manual 100000467, section 5.6 Diagnostic Codes (opens in a new tab)Rinnai Sensei RU199/180/160/130 i and e condensing models; code 11 checks and operating instructions.
- Rinnai: Value Series installation and operation manual 100000258 (opens in a new tab)Rinnai V94i, V94Xi, V75i, V65i, V94e, V75e and V65e non-condensing models; owner and licensed-professional remedies for code 11.
- Rinnai: RE/VE series installation and operation manual 100000722 (opens in a new tab)Rinnai RE and VE 140–199 i and e non-condensing models; code 11 checks.
- Rinnai: Troubleshooting Tankless Water Heater Diagnostic Codes 100000652 (opens in a new tab)Rinnai service manual for trained professionals; code 11 applies to Sensei, Sensei RX/CX and non-Sensei series.
- Rinnai: official document library (opens in a new tab)Select your exact model and owner manual before interpreting a fault or reset procedure.
- PG&E: recognizing and responding to a gas leak (opens in a new tab)Emergency actions for suspected fuel-gas leaks.
Editorial standards and corrections · Prepare a useful service request