Lochinvar Electric Water Heater Troubleshooting

The Short Answer: A Lochinvar electric that will not heat is a tripped disconnect, a popped ECO on a thermostat, a dead element, or the wrong machine in your head. ET light-duty and residential electrics are 240-volt storage tanks, not a Knight boiler and not a Squire indirect. Totally cold is the upper circuit. Short hot then cold is the lower. Lock every heater breaker off. Do not jumper an ECO.

Licensed local technicians

Lochinvar electric tank ice-cold?

Connect with a licensed 24/7 technician in your zip code right now.

No charge to connect. You only pay the plumber you hire.

Search Intent & The Real Problem

The badge says Lochinvar. Showers died. People paste ICON gas flash codes and Armor boiler faults onto a screw-in element tank. Lochinvar (A.O. Smith family) sells electric storage — residential dual-element and commercial ET / light-duty multi-element — plus gas water heaters, Knight/Armor boilers, and Squire indirects that have no electric elements. Read the rating plate. This page is electric storage, no heat. Sister electrics: Bradford White electric. Indirect leak/heat is HTP / SuperStor family, not this article.

They treat every Lochinvar as a gas Knight. They skip the fused disconnect sitting next to the tank, so you “reset the ECO” on a dead 60-amp. They ohm a 4500 W element live. They mix a Squire coil that is waiting on a boiler with an ET that has its own elements. And they tell you to keep clicking the red high-limit — that is how thermostats burn up.

Step-by-Step Troubleshooting

Step 1: Identify the platform — electric tank vs everything else

Badge / plate What it is This page?
Residential electric, two screw-in elements, upper/lower access Dual-element 240 V storage Yes
ET / light-duty commercial electric, front panel, multiple elements Commercial electric storage Yes
Squire / indirect, coil connections, no element doors Boiler-heated tank No — boiler / aquastat
Knight, Armor, Power-Fin, gas train Gas boiler or gas water heater No
Heat pump / hybrid cabinet Different machine Hybrid path, not this
  • What to look for: Model and serial, volts, wattage per element, number of thermostats. A typical residential element is 4500 W at 240 V — ~18.8 A, ~12–13 Ω with power verified dead. Commercial ET elements are whatever the plate says; do not assume 12–13 Ω.
  • Required tools: Flashlight, phone photo of the plate and the wiring diagram inside the cover.

If it is a Squire, stop hunting an ECO behind an element door. The boiler is the heat source.

Step 2: Power path — breaker, fuses, both legs

  • What to look for: Double-pole in the panel and the local disconnect. One pole open: a lamp may glow, elements sit at 120 V and do not heat. Fused disconnects on commercial ET tanks: a single blown fuse looks like a dead heater. Instant trip is a bolted short — do not hold the handle. A breaker that will not reset stays off. Trip after a few minutes is a sheath going to ground as it expands — trips after a few minutes.
  • Required tools: Panel from a dry location. Prove 0 V before the cover.

Never energize a tank you have not filled — turned on without water.

Step 3: ECO / high-limit — one reset after the cause

  • What to look for: Manual-reset ECO on each thermostat (residential dual-element: upper is the one that kills all heat). Commercial ET: ECO on each thermostat/ECO combo; some electronic controls lock out and need a power cycle after the water is below the reset temperature (often ~120 °F). Click once. Repeat trip is a grounded element, a stuck thermostat, or a dry-fire. Do not tape the button. Repeated ECO: keep resetting.
  • Required tools: Breakers locked. Finger on a cool tank.

Electronic residential Lochinvar/A.O. Smith controls can show codes such as an ECO / high-limit event or an upper-element circuit fault — photograph the display. Do not invent gas ICON flash counts.

Step 4: Elements and thermostats — dead, then ohms

  • What to look for: Totally cold: upper element or upper thermostat. Short hot then lukewarm: lower element. With every disconnect locked and wires lifted, ohms per that wattage. 4500 W / 240 V ≈ 12–13 Ω. Any screw-to-shell continuity is a ground. Water in the electrical bucket is a gasket or a leak — leave it off; gasket leak. Lime-eaten sheaths open or ground; they do not “scale back to life” with vinegar while you live in the house.
  • Required tools: Digital meter, both wires lifted, 0 V proven.

Do not replace the upper thermostat because the lower element is open. Measure.

Step 5: Lukewarm, T&P, and a tank that is actually done

  • What to look for: Mixing valve or dip tube if the jacket is hot — that is not an element. T&P dribble: house static over ~80 psi or a waterlogged expansion tank; typical relief 150 psi / 210 °F. Never cap it. Wet jacket, rusty water, years of no anode: the shell is done — bottom leak map. Commercial ET tanks still fail at element gaskets first.
  • Required tools: Hose-bib gauge, paper towel. No sealant on the shell.

When DIY Ends: Calling a Licensed Pro

You may confirm the disconnect, photograph the plate, and press one ECO after a confirmed full tank. Stop at live lugs, contactor panels, repeating high-limits, wet electrical compartments, and any leak from the vessel. Multi-element commercial Lochinvars are electrician-plus-plumber work. A licensed tech with the Lochinvar diagram beats a bag of “universal” elements and a second cooked thermostat.

Frequently Asked Questions

Q: Why is my Lochinvar electric water heater not heating? A: Tripped breaker or fused disconnect, open ECO, dead upper element, or a Squire waiting on a boiler. Prove 240 V dead, then hire a licensed tech if it stays cold.

Q: Where is the reset button on a Lochinvar electric water heater? A: On the thermostat ECO behind the access panel, sometimes one per element. Power off first. One press on a full tank. If it trips again, stop.

Q: Can I replace a Lochinvar electric element myself? A: Only if you can lock 240 V off, drain below the opening, and use the correct gasket and wattage. A spinning tank spud or water in the bucket is a licensed call.