Electric Tankless Goes Cold After a Few Minutes

On this page (7 sections)

The Short Answer: When an electric tankless heater runs hot and then goes cold, the cause is usually flow. Either the demand is more than the heater can warm at today’s inlet temperature, or the flow has dropped below the rate that switches the heater on. Less often, the heater has lost one of its circuits, runs on 208 volts, or has a high-temperature limit that has opened.

Match the pattern to the cause

How the water turns cold is the best clue. Note it before anything is reset.

What happens Most likely cause What to do
Hot at first, then fades to lukewarm; worse in winter or with two fixtures open Flow higher than the heater can warm for the needed temperature rise Reduce flow or simultaneous use; compare with the model’s rise table
Hot, then suddenly cold while water is still running; returns when you turn the tap up Flow fell below the activation threshold Check low-flow heads and the shower valve position
Hot for a few minutes, then cold, then hot again after a pause A self-resetting high limit opening and closing Arrange service; overheating has a cause
Hot, then cold, and stays cold until someone resets it A manual-reset high limit has opened Arrange service; do not open the cover
Never as hot as it used to be, from the first minute One heating circuit, breaker or element not working, or reduced supply voltage Check the panel breakers; technician
Only one shower misbehaves Mixing or pressure-balance valve in that shower Compare with another fixture

Demand above capacity

An electric tankless heater adds a fixed amount of heat. As Bosch’s electric water heater FAQ (opens in a new tab) puts it, the faster the water moves, the less heat it can absorb.

Stiebel Eltron’s Tempra specification sheet (opens in a new tab) shows the size of the effect. It gives the relationship as gpm = kW × 6.83 ÷ temperature rise (°F). A Tempra 24 on 240 volts is listed at a 92°F rise at 1.5 gpm, 54°F at 3.0 gpm and 37°F at 4.5 gpm. At 3.0 gpm, 40°F winter water comes out near 94°F. The same heater and flow with 65°F summer water delivers about 119°F. A heater that was fine in September can feel like it is failing in January.

EcoSmart’s ECO 8 to 36 manual (opens in a new tab) lists a maximum-flow table for a 105°F outlet. For the ECO 27, it lists 2.0 gpm with 40°F inlet water and 3.0 gpm at 50°F. EcoSmart offers outlet flow regulators to hold flow in that range, and Stiebel’s Tempra Plus (not Trend) models trim flow automatically when demand exceeds capacity.

To check your own flow, time how long a shower takes to fill a bucket of known size. Then compare the result with the temperature-rise table for your model and voltage.

Flow below the activation threshold

The heater only switches on when its flow sensor sees enough water moving. Published minimums vary:

  • Stiebel Eltron Tempra: 0.37 gpm for the Tempra 12, 0.50 gpm for the 15, 20 and 24, and 0.77 gpm for the 29 and 36.
  • Bosch TR6100C: 0.5 gpm.
  • EcoSmart ECO models: about 0.3 gpm.

A low-flow shower head, a pressure-balancing valve cutting hot flow as you turn toward cool, another fixture dropping pressure, or a partly blocked inlet screen can each push a fixture under that line mid-shower. EcoSmart’s troubleshooting table notes that anti-scald valves mix in cold water even at full hot, and that many can be adjusted to reduce the cold mix. A mixing valve that is set or adjusted by an installer belongs to that installer or a plumber.

Bosch notes that the Tronic 4000C and TR6100C have a small mesh filter inside the cold-water inlet fitting. If it clogs, it can restrict flow enough to stop the heater activating. Cleaning it means isolating power and water and opening a connection, so have the installer do it unless your manual assigns it to the owner.

Less power than the heater was designed for

  • 208-volt supply. Many apartments and light-commercial buildings have 208-volt service. EcoSmart says its 240-volt models give 75 percent capacity on 208 volts. Bosch says the Tronic 3000 US9 loses about 25 percent of its heating ability at 208 volts. Stiebel lists a Tempra 24 at 24 kW on 240 volts and 18 kW on 208 volts.
  • One circuit off. Larger units are fed by two to four separate double-pole breakers. The EcoSmart ECO 27 needs three 40-amp breakers, and the Tempra 24 needs two 50-amp breakers. If one has tripped, the display can stay lit while part of the heating is missing. Check every breaker labeled for the heater and reset a tripped one once; if it trips again, leave it off. See tankless water heater keeps tripping the breaker.
  • Wiring mistakes on a new install. EcoSmart warns that if the supply wire sets are mixed up, the heater will not work correctly even though it turns on and looks normal.
  • A failed element or control stage. EcoSmart’s table treats “display lights but no heat” as an internal part failure that needs technical support.

High-temperature limits

Overheat protection differs by brand. EcoSmart describes its limits as automatically resetting. Stiebel’s Tempra has a high limit with manual reset on each heating cylinder that interrupts power at 185°F. Bosch says the Tronic 4000C has two thermal cutouts, one automatic and one manual-reset. A limit that opens is a symptom with a cause, and the reset buttons inside the cover are for a qualified technician. If a Stiebel Eltron unit has gone completely dead, see Stiebel Eltron water heater not turning on.

What the technician will check

With power isolated, the technician confirms the supply voltage and that every circuit and element draws current under flow. They check the flow sensor and inlet screen for debris or scale, and check the wiring order on multi-circuit units. They compare actual flow and inlet temperature with the model’s published rise, and review any recorded fault. If the heater is simply too small for winter demand, the options are flow restriction, a second unit or a larger model. A part replacement will not fix that.

For gas tankless heaters and hot-cold-hot surges in general, see why a tankless water heater goes from hot to cold. Low pressure through EcoSmart units is covered in EcoSmart tankless low pressure.

Frequently Asked Questions

Q: Why is my electric tankless fine in summer but cold in winter? A: The heater adds a fixed number of degrees at a given flow. Colder inlet water means a colder outlet. On a Stiebel Tempra 24 at 3.0 gpm, the published 54°F rise gives about 94°F from 40°F water. Reducing flow restores temperature.

Q: Will turning the shower handle toward cold help? A: Often it makes things worse. A pressure-balancing valve reduces hot-water flow as you move toward cold, which can drop the heater below its activation flow and shut it off. Use less total flow with the handle closer to hot instead.

Q: The display is on, so why is the water only lukewarm? A: A lit display does not prove that every heating circuit is working. One tripped breaker on a multi-breaker unit, a 208-volt supply or a failed element can all leave the display on with reduced heat.

Before you call a technician

Write down

  • The heater. Photograph the rating plate: brand, full model number, serial number, and fuel. The serial number usually encodes the manufacture date.
  • The pattern. Is every fixture affected? Is the water cold, briefly hot, or lukewarm? Did it start after an outage, a freeze, plumbing work, or a setting change?

Stop and get help if

  • A breaker that trips again, or a scorched or melted smell: leave it off.
  • Never cap the relief valve, bypass a safety switch, or open gas, electrical, or sealed combustion parts.