Rheem Failed Ignition Lockout: Soft vs Hard Lockout

On this page (6 sections)

The Short Answer: A failed-ignition lockout means the control tried to light the burner several times, never detected a flame, and stopped trying. On Rheem power-vent tanks a soft lockout retries after about five minutes. A hard lockout, after repeated failures, needs power turned off and on. The usual causes are gas supply, the igniter or pilot, or flame sensing. Check the gas supply and reset once.

Which Rheem heaters have this lockout

Standard atmospheric Rheem tanks with a standing pilot and a thermopile don’t use an ignition lockout; their status light reports other faults. The lockout described here applies to Rheem heaters with electronic ignition:

Heater type How the lockout shows How it clears
Power vent with Honeywell electronic control Code 11 (six flashes, then one): failed trial for ignition Soft lockout; retries after about 5 minutes
Same, after repeated soft lockouts Code 10 (six flashes, then five): hard lockout Only by turning power off and on
Super high efficiency condensing tank A001 “Ignition lockout” on the display Turning the unit off and on, per the service manual
Rheem gas tankless Code 11 on the remote See Rheem tankless flashing 11

The power-vent codes and timings come from Rheem’s Technical Bulletin 1627 (opens in a new tab) and the power vent Use & Care manual (opens in a new tab). The condensing A001 code is listed in Rheem’s condensing service manual (opens in a new tab).

Common causes

The power vent manual lists, for both code 11 and code 10: the gas supply is off or too low, then the pilot assembly, then the gas control. TB 1627 adds carbon on the igniter electrode, damaged igniter wiring, and restricted pilot or burner supply tubes. In practice:

  • Gas supply: valve partly closed, propane low, or supply pressure too low when other appliances run.
  • Ignition: a worn or carboned igniter, or a damaged igniter lead.
  • Flame sensing: the flame lights but isn’t detected, so the control shuts it off.
  • After gas work: air in a newly connected line can cause repeated failed trials.

What you can check safely

  1. Note the flash pattern or display code before you do anything.
  2. Confirm the gas valve to the heater is fully open and other gas appliances work. On propane, check the tank.
  3. Make sure the heater is plugged in and the vent termination outside is clear.
  4. If it’s a hard lockout (code 10 or A001), turn power off and back on once. A soft lockout (code 11) will retry on its own.
  5. If it locks out again, leave it off and call for service.

What the technician will check

A technician will measure gas pressure at the heater, watch an ignition attempt, and inspect and clean or replace the igniter and pilot assembly. They also check flame-sensing current and the gas control. The burner door on these heaters is sealed with a gasket, and Rheem says only a qualified technician should remove it and fit a new gasket.

Repair or replace

Lockouts are usually solved with a gas supply correction, a pilot or igniter assembly, or a gas control. Replacement only makes sense if the tank is leaking or the heater has other major failures.

Related: Rheem code 11 on different Rheem heaters and Rheem pressure switch failed open.

Frequently Asked Questions

Q: Why did my Rheem start working again by itself? A: A soft lockout clears after about five minutes and the control tries again. If conditions changed, for example another appliance stopped using gas, it may light. The underlying cause is probably still there.

Q: Can I light it manually while it’s locked out? A: No. Electronic-ignition Rheem heaters aren’t designed to be lit by hand, and the burner chamber is sealed. Call for service if a reset doesn’t work.

Before you call a technician

Write down

  • The heater. Photograph the rating plate: brand, full model number, serial number, and fuel. The serial number usually encodes the manufacture date.
  • The pattern. Is every fixture affected? Is the water cold, briefly hot, or lukewarm? Did it start after an outage, a freeze, plumbing work, or a setting change?

Stop and get help if

  • Gas or rotten-egg smell, or a CO alarm: leave now and call the gas utility or 911 from outside. Do not use switches or try to find the source.
  • A burner bang, flames outside the burner area, soot, or a smell of exhaust: turn the heater off at its control and do not relight it.
  • Never cap the relief valve, bypass a safety switch, or open gas, electrical, or sealed combustion parts.