Noritz Code 12: Flame Loss

On this page (6 sections)

The Short Answer: On Noritz gas tankless heaters, code 12 is “Flame Loss”: the burner lit, then the flame went out or the unit stopped detecting it. Common causes are a gas supply that can’t keep up when the burner fires hard, a propane tank running low, a venting or wind problem, and a dirty flame rod. Check your gas supply and vent, reset once, and call a technician if it returns.

Code 12 versus 11 and 10

Noritz training material lists 11 as ignition failure (the burner never proved flame) and 12 as flame loss (opens in a new tab) (it lit, then lost it). That difference matters. With 12, the ignition system worked at least once, so the question is why the flame couldn’t be sustained.

If your display shows 11, see Noritz code 11. Code 10 relates to combustion and venting.

Common causes of code 12

Pattern Likely cause Who handles it
12 mainly when several fixtures run, or when the furnace is also on Gas line too small or gas pressure dropping under load Gas technician
12 on a propane system, recently or suddenly Tank low, regulator problem, or freezing regulator in cold weather Owner checks tank; supplier or technician for regulator
12 on windy days, outdoor unit Wind affecting the flame or exhaust Technician may recommend a vent or wind accessory
12 with exhaust smell or soot Venting problem or poor combustion Shut down; technician
12 intermittently, gas supply fine Dirty or worn flame rod, or a combustion fan issue Technician
12 since a new installation or gas work Undersized gas line, air in the line, or wrong gas type Installer

Noritz’s EZ series training (opens in a new tab) specifically names an undersized gas line as a cause of 11, 12, and combustion codes. A large tankless burner needs much more gas than a tank heater, and a line that is fine at low fire may not keep up at full fire.

What you can check safely

  1. Write down the code and when it happened: during a single shower, when several taps ran, or in cold or windy weather.
  2. Confirm the gas valve to the heater is fully open and other gas appliances are working.
  3. On propane, check the tank level. Low tanks and cold weather together are a common cause.
  4. Look at the outdoor vent or the outdoor unit for snow, ice, nests, or debris.
  5. Turn the unit off and on with the remote controller (or the power switch) once. If 12 returns, leave it off and call for service.

Repeated resets on a flame fault can send unburned gas through the burner, so don’t keep cycling it.

What the technician will check

A Noritz-qualified technician will measure gas pressure at the heater both at rest and with the burner at full fire, which is the usual way to find an undersized or overloaded gas line. They also inspect and clean the flame rod, check the combustion fan and the vent run, and confirm the unit is set for the correct gas type. On outdoor units they look at how the heater is exposed to wind.

Repair or replace

Most code 12 causes are fixable: a gas line upgrade or regulator, a cleaned or replaced flame rod, venting corrections, or a fan. Replacement is usually only on the table when an older unit also has a failing heat exchanger or repeated control problems.

Related: tankless water heater not working after rain and Noritz tankless water heater not working.

Frequently Asked Questions

Q: Why does code 12 only appear when two showers run? A: That points strongly to the gas supply. At higher demand the burner fires harder and needs more gas. If the line or meter can’t supply it, the flame weakens and the unit records a flame loss.

Q: Can I clean the flame rod myself? A: The flame rod is inside the sealed combustion section behind the front cover. Cleaning or replacing it is a technician job.

Q: Is code 12 dangerous? A: The code itself means the safety system shut the burner off. Treat it as a problem to fix, and if you also smell gas or exhaust, leave and call for help.

Before you call a technician

Write down

  • The heater. Photograph the rating plate: brand, full model number, serial number, and fuel. The serial number usually encodes the manufacture date.
  • The exact code. Photograph the display, or count the flashes and the pause between groups. Note whether the code returns after one reset.
  • The pattern. Is every fixture affected? Is the water cold, briefly hot, or lukewarm? Did it start after an outage, a freeze, plumbing work, or a setting change?

Stop and get help if

  • Gas or rotten-egg smell, or a CO alarm: leave now and call the gas utility or 911 from outside. Do not use switches or try to find the source.
  • A burner bang, flames outside the burner area, soot, or a smell of exhaust: turn the heater off at its control and do not relight it.
  • Never cap the relief valve, bypass a safety switch, or open gas, electrical, or sealed combustion parts.